SPECIFICATIONS |
| | |
|
Dimensions:
|
see individual units
|
Weight:
|
see individual units
|
|
Power Requirements:
|
27.5 VDC at 5.6 amperes nominal; 115VAC, 400Hz, 35VA nominal
|
Circuitry:
|
all solid state, except R/T magnetron tube and indicator CRT
|
|
Ranges:
|
10,25,50,100,200,300 nm (2.5,5,10,50,100,200 for short range version)
|
Operating Frequency:
|
X-Band, 9345 +-30 MHz
|
|
Power Output:
|
Nominal 10kW peak
|
System Noise:
|
7dB nominal
|
|
Pulse Width:
|
1usec in MAP, 10,25 and 50-mile ranges; 3.5 usec on all other ranges and modes
|
Self-Test
|
RANGE switch in TEST position provides color pattern and noise band presentation on 100-nm
range
|