Hurricane Nicole Southeast Aerospace will be closed on Wednesday, October 9th through Thursday, October 10th due to Hurricane Milton.
We are expecting to reopen for business on Friday, October 11th, at 8:00 AM Eastern Time.

Please check our website and social media accounts on Facebook or Linkedin for any additional updates. AOG Services are NOT available.

Picture of product CTL-92

Part #: 622-6523-008

Model: CTL-92

NSN:

5895-01-370-4296

OEM:

Collins Aerospace

Desc:

Transponder Control

Part Number :


CTL-92

 

FEATURES

  • Digital Display Transponder Control designed to tune TDR-94 and TDR-94D transponders but can be used to tune Proline I TDR-90 when used in conjunction with the CAD-62 Control Adapter
  • Serial tune control unit note: CAD-62 Control Adapter converts serial tuning data to parallel tuning data
  • Provides active and preset frequency display
  • Models available with black or gray bezel (see table below)
  • Models available with 5 or 28 volt lighting (see table below)
  • Models available with variations of OFF/STANDBY/ON/ALT selections (see table below)
  • Models available with dual transponder capability for use one control - two transponder configurations (see table below)
  • Models available with Mode S Transponder Compatibility (see table below)
  • Models available with relay control capability for special applications where relay is utilized to operate 2 transponders with one antenna/encoder (see table below)

 

SPECIFICATIONS

Weight: 1.2 lbs. Dimensions: 2.375"W x 2.625"H x 7.52"L
TSO: C37c, C34d, C36d, C38e, C40b, C66b, C41c, C74e RTCA Document: DO-160A
EUROCAE: MPS/WG 8/1/71; ED-14A DEUTSCHE BUNDESPOST FTZ: A446R2010
Environmental: DO-160A categoreis /A2C1/B/PKS/ EXXXXXZ/BZ/AZZ EUROCAE ED-14A Temperature: -30 to +70C
Altitude: 35000 ft. max. Shock: 6 g operational
Power Requirement: 27V dc (16-32) at 0.25A Lighting Power: 5V ac/dc. 350mA or 28Vdc, 100 mA
Lighting Color: Blue-white Display Type: Gas discharge
Brightness Control: Automatic or external potentiometer Electrical Input/Output: EIA RS-422A
Input/Output Format:  Commercial Standard Digital Bus (CSDB)     
Part Number Transponder Control Description:
622-6523-001 5V lighting, gray panel, OFF-STBY-ON-ALT controls, Single transponder capability
622-6523-002 28V lighting, gray panel, OFF-STBY-ON-ALT controls, Single transponder capability
622-6523-003 5V lighting, black panel, OFF-STBY-ON-ALT controls, Single transponder capability
622-6523-004 28V lighting, black panel, OFF-STBY-ON-ALT controls, Single transponder capability
622-6523-005 5V lighting, gray panel, OFF-STBY-ON-ALT controls, Dual transponder capability
622-6523-006 28V lighting, gray panel, OFF-STBY-ON-ALT controls, Dual transponder capability
622-6523-007 5V lighting, black panel, OFF-STBY-ON-ALT controls, Dual transponder capability
622-6523-008 28V lighting, black panel, OFF-STBY-ON-ALT controls, Dual transponder capability
622-6523-009 5V lighting, gray panel, STBY-ON-ALT controls, Single transponder capability
622-6523-010 28V lighting, gray panel, STBY-ON-ALT controls, Single transponder capability
622-6523-011 5V lighting, black panel, STBY-ON-ALT controls, Single transponder capability
622-6523-012 28V lighting, black panel, STBY-ON-ALT controls, Single transponder capability
622-6523-013 5V lighting, gray panel, STBY-ON-ALT controls, Dual transponder capability
622-6523-014 28V lighting, gray panel, STBY-ON-ALT controls, Dual transponder capability
622-6523-015 5V lighting, black panel, STBY-ON-ALT controls, Dual transponder capability
622-6523-016 28V lighting, black panel, STBY-ON-ALT controls, Dual transponder capability
622-6523-201 5V lighting, gray panel, OFF-STBY-ON-ALT controls, Single transponder capability, Mode S compatible
622-6523-202 28V lighting, gray, OFF-STBY-ON-ALT controls, Single transponder capability, Mode S compatible
622-6523-203 5V lighting, black, OFF-STBY-ON-ALT controls, Single transponder capability, Mode S compatible
622-6523-204 28V lighting, black, OFF-STBY-ON-ALT controls, Single transponder capability, Mode S compatible
622-6523-205 5V, gray, OFF-STBY-ON-ALT ctls, Dual transponder cap., Mode S compatible, Relay control capability
622-6523-206 28V, gray, OFF-STBY-ON-ALT ctls, Dual transponder cap., Mode S compat, Relay control capability
622-6523-207 5V, black, OFF-STBY-ON-ALT ctls, Dual transponder cap., Mode S compat, Relay control capability
622-6523-208 28V, black, OFF-STBY-ON-ALT ctls, Dual transponder cap., Mode S compat, Relay control capability
622-6523-209 5V lighting, gray, STBY-ON-ALT controls, Single transponder capability, Mode S compatible
622-6523-210 28V lighting, gray, STBY-ON-ALT controls, Single transponder capability, Mode S compatible
622-6523-211 5V lighting, black, STBY-ON-ALT controls, Single transponder capability, Mode S compatible
622-6523-212 28V lighting, black, STBY-ON-ALT controls, Single transponder capability, Mode S compatible
622-6523-213 5V, gray, STBY-ON-ALT controls, Dual transponder cap., Mode S compatible, Relay control capability
622-6523-214 28V, gray, STBY-ON-ALT controls, Dual transponder cap., Mode S compatible, Relay control capability
622-6523-215 5V, black, STBY-ON-ALT controls, Dual transponder cap., Mode S compatible, Relay control capability
622-6523-216 28V, black, STBY-ON-ALT controls, Dual transponder cap., Mode S compat, Relay control capability
622-6523-305 5V, gray, OFF-STBY-ON-ALT controls, Dual transponder cap., Mode S compat, Relay control cap.
622-6523-306 28V, gray, OFF-STBY-ON-ALT controls, Dual transponder cap., Mode S compat, Relay control cap.
622-6523-307 5V, black, OFF-STBY-ON-ALT controls, Dual transponder cap., Mode S compat, Relay control cap.
622-6523-308 28V, black, OFF-STBY-ON-ALT controls, Dual transponder cap., Mode S compat, Relay control cap.
622-6523-313 5V, gray, STBY-ON-ALT controls, Dual transponder cap., Mode S compat, Relay control cap.
622-6523-314 28V, gray, STBY-ON-ALT controls, Dual transponder cap., Mode S compat, Relay control cap.
622-6523-315 5V, black, STBY-ON-ALT controls, Dual transponder cap., Mode S compat, Relay control cap.
622-6523-316 28V, black, STBY-ON-ALT controls, Dual transponder cap., Mode S compat, Relay control cap.


PLEASE NOTE: THE ABOVE LISTED PART NUMBERS REFLECT THE DIFFERENT UNITS ORIGINALLY AVAILABLE BY THE MANUFACTURER AND DO NOT NECESSARILY INDICATE OR REFLECT THE CURRENT AVAILBILITY OF THESE DIFFERENT UNITS BY SOUTHEAST AEROSPACE OR THE AFTERMARKET

 

 

 

622-6523-004
- Transponder Control

NSN: 1440-01-316-6427

Price Condition Status
$2,200.00 OH OUTRIGHT 1 IN STOCK
622-6523-204
- Transponder Control
Price Condition Status
$2,750.00 OH OUTRIGHT 1 IN STOCK
622-6523-001
- Transponder Control

NSN: 1440-01-423-9207

Price Condition Status
REQUEST OH OUTRIGHT REQUEST LEAD TIME
622-6523-002
- Transponder Control
Price Condition Status
RFQ RFQ RFQ
622-6523-003
- Transponder Control

NSN: 5895-01-372-5176

Price Condition Status
REQUEST OH OUTRIGHT REQUEST LEAD TIME
622-6523-005
- Transponder Control

NSN: 5821-01-333-9236

Price Condition Status
REQUEST OH OUTRIGHT REQUEST LEAD TIME
622-6523-006
- Transponder Control
Price Condition Status
REQUEST OH OUTRIGHT REQUEST LEAD TIME
622-6523-007
- Transponder Control

NSN: 5985-01-304-3754

Price Condition Status
REQUEST OH OUTRIGHT REQUEST LEAD TIME
622-6523-008
- Transponder Control

NSN: 5895-01-370-4296

Price Condition Status
REQUEST OH OUTRIGHT REQUEST LEAD TIME
622-6523-201
- Transponder Control
Price Condition Status
REQUEST OH OUTRIGHT REQUEST LEAD TIME
622-6523-202
- Transponder Control

NSN: 5895-01-424-3790

Price Condition Status
REQUEST OH OUTRIGHT REQUEST LEAD TIME
622-6523-203
- Transponder Control
Price Condition Status
REQUEST OH OUTRIGHT REQUEST LEAD TIME
622-6523-205
- Transponder Control

NSN: 5895-01-498-5233

Price Condition Status
REQUEST OH OUTRIGHT REQUEST LEAD TIME
622-6523-206
- Transponder Control
Price Condition Status
REQUEST OH OUTRIGHT REQUEST LEAD TIME
622-6523-207
- Transponder Control

NSN: 5895-01-497-8158

Price Condition Status
RFQ RFQ RFQ
622-6523-208
- Transponder Control
Price Condition Status
REQUEST OH OUTRIGHT REQUEST LEAD TIME

Click on a question below to see the answer. If you have a question about this model that is not answered below, please contact questions@seaerospace.com


In relation to NE (New) parts, many OEMs change their prices and availability without any notice to dealers or the industry. Therefore, through the REQUEST or RFQ indication, we ask that customers contact us for the most accurate price and availability.

In relation to SV & OH parts, the used parts aftermarket in the aviation industry is not an infinite supply. It is a dynamic, constantly changing market that is significantly affected by and susceptible to highs and lows in supply and demand. Therefore, although we attempt to, at times, we are unable to predict the exact moment when an item may be available. Once again, through the REQUEST or RFQ indication on our website, we ask that customers contact us for the most current and accurate price and availability.

Negotiating the exchange price of a unit only limits the allowable repair cap for the core unit. Southeast Aerospace's exchange transactions are based on the return of economically repairable core unit. Once the core is received and evaluated, the core repair cost incurred by SEA cannot exceed 75% of the original exchange price. That is, it cannot cost SEA more than 75% of the original OH/SV exchange price collected from the customer. Therefore, when and if an SEA exchange price is discounted, there is a risk that additional charges may be assessed once the core is returned and evaluated.

The CTL-X0 is 30-40 years old. Service parts from Collins are either no longer available or extremely expensive. It is not cost effective nor possible in some situations to continue to utilize the CTL-X0 controls in your aircraft. Southeast Aerospace recommends converting the CTL-X0 controls over to the Collins CTL-X2 Proline II controls.

The CTL-X2 is not a direct replacement for the CTL-X0 controls. A connector change, CAD adapter, and locally fabricated panel filler plate are required for the change. A qualified avionics technician should perform this modification. While this is a moderately involved retrofit, it is a change that is eminent and will ultimately be required if you continue to use your original Proline I radios.

  • To convert from the CTL-20 Comm control, the CTL-22, CAD-31, mating connectors, and CAD bracket are required.
  • To convert from the CTL-30 Nav control, the CTL-32, CAD-31, mating connectors, and CAD bracket are required.
  • To convert from the CTL-60 ADF control, the CTL-62, CAD-62, mating connectors, and CAD bracket are required.
  • To convert from the CTL-90 Transponder control, the CTL-92, CAD-62, mating connectors, and CAD bracket are required.

For an exact SEA quote to convert from your CTL-X0 control, please provide the part number of your CTL-X0. Contact SEA with this information and an SEA rep will provide a quotation immediately.

If dashes are present in the lower display, please use the following steps:
  • Push and hold the "ACT" button until a frequency appears
  • Momentarily push the "XFR/MEM" switch to "MEM" position to select the desired channel number
  • Tune to the desired frequency and push "STO" button 2 times to store the frequency
  • Press "RETURN" to continue